• OPEN ACCESS

Irreversible Electroporation for Hepatocellular Carcinoma Abutting the Diaphragm: A Prospective Single-center Study

  • Yangyang Ma1,
  • Zhixian Chen2,
  • Bing Liang3,
  • Rongrong Li4,
  • Jianyu Li3,
  • Zhonghai Li5,
  • Mao Lin1,* and
  • Lizhi Niu2,*
 Author information
Journal of Clinical and Translational Hepatology 2022;10(2):190-196

DOI: 10.14218/JCTH.2021.00019

Abstract

Background and Aims

Irreversible electroporation (IRE) is an emerging local ablation therapy which may be effective for unresectable tumors. This study aimed to evaluate the safety and efficacy of percutaneous IRE in the treatment of hepatocellular carcinoma (HCC) abutting the diaphragm.

Methods

A total of 26 participants with 39 tumors abutting the diaphragm were prospectively evaluated between July 2015 and September 2018. Complications associated with IRE were recorded, and the survival benefit of IRE was analyzed. The factors associated with time to local tumor progression (LTP) were analyzed using univariate and multivariate Cox regression models.

Results

No major complications or treatment-related deaths occurred. The technical success rate was 96.2% (25/26) and complete ablation rate was 92.3% (36/39). The median follow-up period was 16.7 months (range: 3.0–43.0 months), the LTP occurred in 15.2% of tumors and median time to LTP was 20.4 months. Overall, tumor size (hazard ratio: 1.24 [95% confidence interval: 0.38, 3.81], p=0.03) was the only factor associated with time to LTP.

Conclusions

This study shows for the first time that percutaneous IRE is a safe and effective ablation technology for HCC abutting the diaphragm.

Keywords

Irreversible electroporation, Hepatocellular carcinoma, Diaphragm, Safety, Efficacy

Introduction

Hepatocellular carcinoma (HCC) is the third most common cause of cancer-related deaths globally.1–3 In addition, the incidence rate of HCC has been on the rise and is anticipated to continue increasing.4,5 The 5-year survival rate of untreated HCC is below 5%.3 Surgical resection and radiofrequency ablation are the recommended therapeutic strategies for early-stage HCC patients.6

Treatment of HCC abutting the diaphragm is challenging, due to poor visibility of the target tumor, difficulty in access, and risk of collateral thermal injury to surrounding structures.7 Radiofrequency ablation, cryoablation, microwave ablation and other thermal ablation methods are the commonly used local treatment strategies for HCC abutting the diaphragm.8–10 A few studies have reported that using conventional radiofrequency ablation resulted in a low local tumor control and high complication rate (mainly pneumothorax or diaphragm injury, lung injury) for HCC abutting the diaphragm.11–14 Thus, percutaneous thermal ablation of HCC abutting the diaphragm may result in poor clinical outcomes. However, to date, no reported study has investigated the application of irreversible electroporation (IRE) for treatment of HCC abutting the diaphragm.

IRE is a novel non-thermal ablation technology that uses high-voltage short pulses to influence the target cell membrane, forming irreversible nanopores on the lipid bilayer of the cell membrane. This in turn disrupts the steady state of the intracellular environment, subsequently leading to cell death.15–17 Moreover, the main advantage of IRE is that it can treat tumors very close to large blood vessels and bile ducts without affecting blood or bile flow, mainly because it has a non-thermal effect in the treatment zone.18

Therefore, this study aimed to evaluate the safety and efficacy of percutaneous IRE in unresectable HCC abutting the diaphragm. We hypothesized that IRE could be a better choice for HCC abutting the diaphragm.

Methods

The present prospective study (NCT02329106) was approved by the ethics committee of the Institutional Review Board of Fuda Cancer Hospital. The study was conducted in compliance with the Helsinki Declaration, and written informed consent was obtained from all patients.

Patient selection

A total of 26 patients (median age: 62 years; range: 45–75 years) with 39 tumors were enrolled for the study between July 2015 and September 2018. HCC was diagnosed according to the practice guidelines of the American Association for the Study of Liver Diseases (AASLD).19 Computed tomography (CT) images were used to measure the shortest distance from the edge of the tumor to the diaphragm. The inclusion criteria were as follows: (1) subphrenic HCC (defined as a tumor adjacent to the diaphragm [<10 mm] on axial or coronal CT or magnetic resonance [MR] imaging); (2) tumor size of ≤5 cm; (3) tumor location adjacent to the diaphragm and unable to be subjected to surgical resection or with patient refusal to undergo surgical resection; (4) absence of portal vein tumor thrombus or formation of stubborn malignant ascites; and (5) adequate liver function (Child-Pugh classification of grade A or grade B). The following exclusion criteria were adopted: (1) intolerance to general anesthesia; (2) presence of a pacemaker or biliary metal stents; or (3) diagnosis of arrhythmias, epilepsy and myocardial injury.

IRE procedure

Preoperative preparation involved a 64-slice spiral CT (SOMATOM Definition AS; Siemens Healthcare, Erlangen, Germany), enhanced CT examination and 1.5 T superconducting MR scans, performed to determine whether the tumor was associated with unilateral or bilateral secondary bile ducts, portal veins and other vital structures without distant metastasis, and to confirm that there were no radical surgical resection conditions. Anesthetization included induction medications of midazolam, etomidate, sufentanil and vecuronium under mechanical ventilation of 60% oxygen concentration. Remifentanil and propofol, in combination with a small amount of isoflurane inhalation, was administered as maintenance medication, and intermittent addition of vecuronium was applied to achieve full muscle relaxation.

After routine aseptic techniques and anesthesia, IRE ablation was performed using the IRE ablation system (NanoKnife; AngioDynamics, Latham, NY, USA) under ultrasound (US) alone or US fused with CT. Electrodes were inserted into lesions under imaging guidance. The number of electrodes used ranged from two to six and was based on the axial maximum tumor size, the distance between adjacent electrodes (1.0–2.0 cm), and exposure length of the ablation electrode (1.0–2.5 cm). To prevent pulse-induced arrhythmias, the IRE generator was synchronized with the patient’s cardiac rhythm. Ablation parameters included voltage 1,500–3,000 V in 10 groups of 90 pulses, and the pulse width for each group was 90 µs. Successful completion of the procedure was defined as the ability to successfully deliver all planned pulses (at least 90) in accordance with the size and dimensions of the lesion as well as to ensure that the current showed a change of at least 5 A from that of the initial 10 pulses delivered. Patient’s vital signs were closely monitored during IRE, and the type of anesthesia administered and other surgery-related accidents or complications were recorded.

Patient follow-up

Patients remained hospitalized for at least 24 h after receiving the IRE ablation treatment. Routine laboratory tests were performed, including liver function test for alpha fetoprotein (AFP) level. The CT and MR imaging were carried out to assess imaging changes. The first assessment was performed 1 month after the IRE procedure, and subsequent assessments were performed every 3 months. Follow-up images were independently interpreted by a senior radiologist with at least 10 years of liver imaging experience. Any tumor observed in the follow-up imaging was reviewed during the weekly multidisciplinary HCC oncology committee meetings.

Evaluation of complications

Adverse events that occurred during the perioperative period, such as pain, fever, or abnormal laboratory results were recorded. Complications were classified as minor and major, in line with the guidelines of the Society of Interventional Radiology Standards of Practice Committee.20 Major complications were defined as any event that led to death or was life-threatening, required surgical or radiological interventions or prolonged hospitalization. All other complications were considered as minor complications.

Evaluation of technical success and treatment effectiveness

Technical success was defined as the evaluation of complete ablation rate observed via CT and MR imaging 1 month after the IRE procedure. Complete ablation was defined as the absence of visible nodules or irregular enhancements near the ablation zone in the arterial phase. During IRE treatment, the technical characteristics of the IRE procedure, including average voltage, number of electrodes, and total number of pulses delivered between each combination of electrodes for each procedure, were recorded.

Evaluation of tumor control

After administration of IRE ablation treatment, the presence of irregular regional enhancement within 1 cm of the ablation area in the arterial phase, nodule enlargement or identification of new contrast enhancement areas during the follow-up period reflected local tumor progression (LTP). Time to LTP was defined as the date from IRE ablation administration to the date of the first observation of LTP.

Evaluation of tumor response

Treatment response was evaluated using contrast-enhanced CT or MR imaging and the guidelines of the modified Response Evaluation Criteria in Solid Tumors (mRECIST). Arterial phase enhanced imaging revealed that the target lesions were not observed in complete response (CR). Partial response (PR) was reflected by a ≥30% decrease in the sum of diameters of the target lesions. Progressive disease (PD) was reflected by a ≥20% increase in the sum of diameters of target lesions or new lesions. Stable disease (SD) manifested target lesions that were not decreased to PR or increased to PD.

Statistical analysis

Data analyses were performed using SPSS version 20.0 (IBM Corp., Armonk, NY, USA). Patient demographics, tumor characteristics, and recurrences were analyzed using descriptive statistics. The median time to LTP was analyzed using the Kaplan-Meier method. Univariate and multivariate Cox regression models were used to estimate crucial baseline tumor parameters for time to LTP. A p-value of <0.05 was considered statistically significant.

Results

Patient characteristics

A total of 35 patients with HCC abutting the diaphragm were evaluated by the multidisciplinary tumor board between July 2015 and September 2018. Amon them, nine patients were excluded due to tumor size ≥5 cm (n=5), the presence of a metal biliary stent or heart pacemaker (n=2), presence of arrhythmias (n=1), or history of epilepsy (n=1). All 26 patients (16 males, 10 females) with 39 tumors underwent the IRE procedure (Fig. 1). Baseline characteristics of the patients are summarized in Table 1. The median age of patients was 62 years (range: 45–75 years). The median size of the tumors was 2.4 cm (range: 1.3–4.2 cm). All tumors were located adjacent to the diaphragm, with a median distance from the diaphragm of 0.56 cm (range: 0.16–1.0 cm). Of the 20 (76.9%) patients who underwent surgery, 11 (42.3%) received transarterial chemoembolization (TACE) before IRE. Representative CT images of HCC abutting the diaphragm before, during, and 40 months after performance of the IRE procedure are displayed (Fig. 2). No patient was lost to follow-up.

Flowchart of patient selection.
Fig. 1  Flowchart of patient selection.
Table 1

Baseline characteristics of eligible patients

CharacteristicValue, n=26
Median age in years, mean (range)62 (45–75)
Sex, n (%)
  Male16 (61.5)
  Female10 (38.5)
Number of tumors39
Tumor size, median (range)2.4 (1.3–4.2)
AFP level in ng/mL86.2 (2–1,562)
Median distance from diaphragm in cm, mean (range)0.56 (0.16–1.0)
ECOG performance status >1, n (%)8 (30.7)
Child-Pugh class, n (%)
  A20 (76.9)
  B6 (23.1)
Tumor location, (%)
  S816
  S711
  S57
  S43
  S22
Prior therapy
  Surgery20
  TACE11
A 49 year-old male with HCC abutting the diaphragm.
Fig. 2  A 49 year-old male with HCC abutting the diaphragm.

(A) Preoperative enhanced CT illustrating location of the tumor adjacent to the diaphragm (arrow). (B) Two ablation electrodes inserted into the tumor area under the guidance of enhanced CT. (C) 6 months after IRE. (D) 40 months after IRE. The ablation zone has shrunk (arrow).

IRE procedure characteristics

During IRE ablation, two to six electrodes (median of three electrodes) were inserted into the ablation area under the guidance of CT coupled with US. Electrodes were placed at 10–20 mm intervals (median interval: 15 mm). Median energy delivery time was 20 m (range: 10–30 m) (Table 2).

Table 2

IRE characteristics

CharacteristicValue
No. of electrodes, median3 (2–5)
Pulse length in µs70–90
No. of pulses (range)1,800 (180–3,800)
Electrode exposure length in mm20 (15–25)
Median voltage2,600 (1,500–3,000)
Median electrode spacing in mm (range)15 (10–20)
Median length of active tip in mm (range)20 (10–25)
Median energy delivery time in m (range)20 (10–30)

Safety

No major complications or deaths associated with IRE occurred. During the follow-up period, all postoperative complications were minor, with adverse reaction levels ranging from 1 to 2 (Table 3). Five patients (19.2%) developed IRE treatment-related cardiac arrhythmia during IRE, eight patients (30.7%) showed elevated blood pressure which was controlled with nicardipine, and six patients (23.1) developed pneumothorax without chest drain. All patients were in remission after general symptomatic treatment.

Table 3

Adverse reactions after treatment

Adverse eventGrade (n, %)
Total (n, %)
IIIIIIIV
Pneumothorax2 (7.7)4 (15.4)006 (23.0)
Cardiac arrhythmia2 (7.7)2 (7.7)004 (15.3)
Pleural effusion01 (3.8)001 (3.8)
Elevated blood pressure2 (7.7)6 (23.0)008 (30.7)
Partial portal Thrombosis01 (3.8)001 (3.8)
Abdominal pain1 (3.8)2 (7.7)003 (11.5)
Fever1 (3.8)0001 (3.8)
Vomiting1 (3.8)1 (3.8)002 (7.7)
Decreased platelet count01 (3.8)001 (3.8)

Efficacy

The technical success rate was 96.2% (25/26) for the initial session. Thirty-six tumors (92.3%) achieved complete ablation (Table 4). The median follow-up period was 16.7 months (range: 3.0–43.0 months). LTP occurred in 6 of the 39 tumors (15.4%); among these, LTP occurred in 2 of the 25 tumors (8.0%) with size of <3 cm and 4 of the 14 tumors (28.6%) with size of >3 cm. The median time to LTP was 20.4 months (range: 3.0–41.2 months) (Fig. 3). Results of univariate analyses revealed that AFP level (hazard ratio [HR]=8.72 [95% confidence interval (CI): 2.97, 13.30]; p=0.03), vascular invasion (HR=2.58 [95% CI: 1.10, 4.21]; p=0.02), and overall tumor size (HR=0.78 [95% CI: 0.45, 1.86]; p=0.01) were significantly associated with time to LTP. However, multivariate analyses results revealed that only overall tumor size of >3 cm (HR: 1.24 [95% CI: 0.38, 3.81]; p=0.03) was significantly associated with time to LTP (Table 5).

Table 4

Treatment responses of the tumors

Treatment responsesTotalCRPRSDPD
Number of tumor3936210
Percentage10092.35.12.60
Graph representing time to local tumor progression in 26 patients with 39 tumors after IRE.
Fig. 3  Graph representing time to local tumor progression in 26 patients with 39 tumors after IRE.
Table 5

Factors associated with time to local tumor progression after IRE

CharacteristicsUnivariate analysis
Multivariate analysis
HR (95% CI)pHR (95% CI)p
Age >60 years0.82 (0.51–1.45)0.67
Cirrhosis1.40 (0.51–2.87)0.71
No prior treatment1.21 (0.49, 3.04)0.86
AFP level >200 ng/mL8.72 (2.97, 13.30)0.031.263 (0.789–2.354)0.06
More than one nodule0.76 (0.23, 3.20)0.61
Vascular invasion2.58 (1.10–4.21)0.022.48 (0.79–4.96)0.22
Overall tumor size >3 cm0.78 (0.45–1.86)0.011.24 (0.38, 3.81)0.03

Discussion

The results of the present study indicated that IRE ablation was a safe and effective treatment method for HCC abutting the diaphragm. About 92.3% of the tumors achieved complete ablation and 15.4% of the patients experienced LTP. Moreover, the median time to LTP was 20.4 months, and multivariate analyses results revealed that only overall tumor size (>3 cm) was associated with time to LTP.

No IRE-related deaths occurred in the present study. Diaphragmatic perforation and other serious adverse events were not observed in the study. Five patients developed cardiac arrhythmia, which resolved once the released pulse ended and after nicardipine treatment. The cases of arrhythmia were caused by the high-voltage electric field which induced bioelectrical disturbance in the body. This underscores the need for cardiac synchronization in such patients.21 Two patients had pneumothorax caused by electrode puncture of the lung. These results suggested that IRE could be considered as a treatment option in the treatment of patients with HCC abutting the diaphragm.

Surgery is the standard treatment procedure for early-stage HCC. However, only less than 20% of the patients are suitable for surgery.2,22 For patients who are not suitable for surgery, radiofrequency ablation is considered as a safe and effective therapy for early-stage HCC.23 However, radiofrequency ablation has heat-sink effect and hence cannot protect vital structures well.24,25 To avoid these limitations, IRE has been proposed as a safer alternative, as it does not cause damage to bile ducts or blood vessels and vital structures.26,27 Moreover, radiofrequency ablation with infusion of artificial ascites creates a buffer zone and isolates vital structures, such as the diaphragm, stomach, bowel loops and gallbladder. However, artificial ascites increases the risk of additional trauma during radiofrequency ablation. The technical success rate of artificial ascites has been low. More importantly, artificial ascites themselves may increase the risk of peritoneal seeding.28 Therefore, IRE ablation could be a potential treatment option for HCC abutting the diaphragm.

Tumor location is an important factor affecting local tumor control. In the present study, the LTP was achieved for 15.4% of lesions. Kang et al.13 retrospectively analyzed 80 patients who underwent a percutaneous radiofrequency ablation with tumor diameters of <4 cm and abutting the diaphragm. LTP was observed in 29% of the lesions. Makovich et al.29 retrospectively analyzed 38 HCC patients who underwent a percutaneous microwave ablation of lesions (≤5 mm from diaphragm) abutting the diaphragm. LTP occurred in 23.7% of the lesions. Yang et al.30 reported on 61 patients (with 77 lesions) who were treated with percutaneous cryoablation. LTP was observed in 41.9% of the lesions. To sum up, all these results suggested that the rate of LTP from IRE was significantly lower than that from radiofrequency ablation, microwave ablation, and cryoablation. Hence, percutaneous IRE appears to be a better choice for HCC abutting the diaphragm.

In the present study, the complete ablation rate was 92.3%. Sutter and his colleagues31 retrospectively analyzed 58 patients with HCC and 75 lesions who underwent IRE ablation. They found the complete ablation rate to be 77.3%, which was nearly 81.8% for lesions with diameters <30 mm. Fruhling et al.32 found a complete ablation rate of 78.9% at 3 months after receipt of IRE and 65.8% at 6 months after. These preliminarily clinical data indicate that IRE ablation can effectively treat HCC-abutting diaphragm tumors, with good complete ablation rates.

In summary, this is the first study to demonstrate that IRE is a safe and effective treatment option for HCC abutting the diaphragm. Furthermore, compared with other ablation techniques, IRE has a lower LTP rate and higher survival benefit for HCC abutting the diaphragm. However, this study has some limitations, such as the small sample size. Future multicenter studies are advocated to validate the present findings.

Abbreviations

AASLD: 

American Association for the Study of Liver Diseases

AFP: 

alpha fetoprotein

CI: 

confidence interval

CR: 

complete response

CT: 

computed tomography

DCR: 

disease control rate

ECOG: 

Eastern Cooperative Oncology Group

HCC: 

hepatocellular carcinoma

HR: 

hazard ratio

IRE: 

irreversible electroporation

LTP: 

local tumor progression

MR: 

magnetic resonance

mRECIST: 

modified Response Evaluation Criteria in Solid Tumors

PD: 

progressive disease

PR: 

partial response

SD: 

stable disease

TACE: 

transarterial chemoembolization

US: 

ultrasound

Declarations

Acknowledgement

We thank all the patients and their families for supporting the study. We also thank the staff in our hospital for their assistance.

Data sharing statement

All data are available upon request.

Funding

This study was supported by grants from the International Science Foundation of Affiliated Fuda Cancer Hospital, Jinan University (No. Y2018-ZD-01).

Conflict of interest

The authors have no conflict of interests related to this publication.

Authors’ contributions

Designed the research (LN, ML), conducted the research (ZC, JZ, YM), analyzed the data (YM, ML), wrote the paper and took primary responsibility for its final content (YM, ML). All authors read and approved the final manuscript.

References

  1. Bruix J, Reig M, Sherman M. Evidence-based diagnosis, staging, and treatment of patients with hepatocellular carcinoma. Gastroenterology 2016;150(4):835-853 View Article PubMed/NCBI
  2. Orcutt ST, Anaya DA. Liver resection and surgical strategies for management of primary liver cancer. Cancer Control 2018;25(1):1073274817744621 View Article PubMed/NCBI
  3. Siegel RL, Miller KD, Jemal A. Cancer statistics, 2020. CA Cancer J Clin 2020;70(1):7-30 View Article PubMed/NCBI
  4. Ayuso C, Rimola J, Vilana R, Burrel M, Darnell A, García-Criado Á, et al. Diagnosis and staging of hepatocellular carcinoma (HCC): current guidelines. Eur J Radiol 2018;101:72-81 View Article PubMed/NCBI
  5. Bertuccio P, Turati F, Carioli G, Rodriguez T, La Vecchia C, Malvezzi M, et al. Global trends and predictions in hepatocellular carcinoma mortality. J Hepatol 2017;67(2):302-309 View Article PubMed/NCBI
  6. Bruix J, Sherman M. Management of hepatocellular carcinoma: an update. Hepatology 2011;53(3):1020-1022 View Article PubMed/NCBI
  7. Wood TF, Rose DM, Chung M, Allegra DP, Foshag LJ, Bilchik AJ. Radiofrequency ablation of 231 unresectable hepatic tumors: indications, limitations, and complications. Ann Surg Oncol 2000;7(8):593-600 View Article PubMed/NCBI
  8. Qi C, Gao H, Zhao Q, Zhang L. Computed tomography-guided percutaneous cryoablation for subcardiac hepatocellular carcinoma: Safety, efficacy, therapeutic results and risk factors for survival outcomes. Cancer Manag Res 2020;12:3333-3342 View Article PubMed/NCBI
  9. Soliman AF, Abouelkhair MM, Hasab Allah MS, El-Kady NM, Ezzat WM, Gabr HA, et al. Efficacy and safety of microwave ablation (MWA) for hepatocellular carcinoma (HCC) in difficult anatomical sites in Egyptian patients with liver cirrhosis. Asian Pac J Cancer Prev 2019;20(1):295-301 View Article PubMed/NCBI
  10. Wang Y, Deng T, Zeng L, Chen W. Efficacy and safety of radiofrequency ablation and transcatheter arterial chemoembolization for treatment of hepatocellular carcinoma: A meta-analysis. Hepatol Res 2016;46(1):58-71 View Article PubMed/NCBI
  11. Kang TW, Rhim H, Lee MW, Kim YS, Choi D, Lee WJ, et al. Radiofrequency ablation for hepatocellular carcinoma abutting the diaphragm: comparison of effects of thermal protection and therapeutic efficacy. AJR Am J Roentgenol 2011;196(4):907-913 View Article PubMed/NCBI
  12. Song KD, Lim HK, Rhim H, Lee MW, Kang TW, Paik YH, et al. Hepatic resection vs percutaneous radiofrequency ablation of hepatocellular carcinoma abutting right diaphragm. World J Gastrointest Oncol 2019;11(3):227-237 View Article PubMed/NCBI
  13. Kang TW, Rhim H, Kim EY, Kim YS, Choi D, Lee WJ, et al. Percutaneous radiofrequency ablation for the hepatocellular carcinoma abutting the diaphragm: assessment of safety and therapeutic efficacy. Korean J Radiol 2009;10(1):34-42 View Article PubMed/NCBI
  14. Kim YS, Rhim H, Sung JH, Kim SK, Kim Y, Koh BH, et al. Bronchobiliary fistula after radiofrequency thermal ablation of hepatic tumor. J Vasc Interv Radiol 2005;16(3):407-410 View Article PubMed/NCBI
  15. Lee EW, Chen C, Prieto VE, Dry SM, Loh CT, Kee ST. Advanced hepatic ablation technique for creating complete cell death: irreversible electroporation. Radiology 2010;255(2):426-433 View Article PubMed/NCBI
  16. Lee EW, Thai S, Kee ST. Irreversible electroporation: a novel image-guided cancer therapy. Gut Liver 2010;4(Suppl 4):S99-S104 View Article PubMed/NCBI
  17. Stillström D, Beermann M, Engstrand J, Freedman J, Nilsson H. Initial experience with irreversible electroporation of liver tumours. Eur J Radiol Open 2019;6:62-67 View Article PubMed/NCBI
  18. Narayanan G, Bhatia S, Echenique A, Suthar R, Barbery K, Yrizarry J. Vessel patency post irreversible electroporation. Cardiovasc Intervent Radiol 2014;37(6):1523-1529 View Article PubMed/NCBI
  19. Bruix J, Sherman M. Management of hepatocellular carcinoma. Hepatology 2005;42(5):1208-1236 View Article PubMed/NCBI
  20. Ahmed M, Solbiati L, Brace CL, Breen DJ, Callstrom MR, Charboneau JW, et al. Image-guided tumor ablation: standardization of terminology and reporting criteria—a 10-year update. Radiology 2014;273(1):241-260 View Article PubMed/NCBI
  21. O’Neill CH, Martin RCG. Cardiac synchronization and arrhythmia during irreversible electroporation. J Surg Oncol 2020;122(3):407-411 View Article PubMed/NCBI
  22. Akgül Ö, Çetinkaya E, Ersöz Ş, Tez M. Role of surgery in colorectal cancer liver metastases. World J Gastroenterol 2014;20(20):6113-6122 View Article PubMed/NCBI
  23. Kim YS, Lim HK, Rhim H, Lee MW, Choi D, Lee WJ, et al. Ten-year outcomes of percutaneous radiofrequency ablation as first-line therapy of early hepatocellular carcinoma: analysis of prognostic factors. J Hepatol 2013;58(1):89-97 View Article PubMed/NCBI
  24. Chen R, Lu F, Wu F, Jiang T, Xie L, Kong D. An analytical solution for temperature distributions in hepatic radiofrequency ablation incorporating the heat-sink effect of large vessels. Phys Med Biol 2018;63(23):235026 View Article PubMed/NCBI
  25. Zhu F, Rhim H. Thermal ablation for hepatocellular carcinoma: what’s new in 2019. Chin Clin Oncol 2019;8(6):58 View Article PubMed/NCBI
  26. Mafeld S, Wong JJ, Kibriya N, Stenberg B, Manas D, Bassett P, et al. Percutaneous irreversible electroporation (IRE) of hepatic malignancy: A bi-institutional analysis of safety and outcomes. Cardiovasc Intervent Radiol 2019;42(4):577-583 View Article PubMed/NCBI
  27. Savic LJ, Chapiro J, Hamm B, Gebauer B, Collettini F. Irreversible electroporation in interventional oncology: Where we stand and where we go. Rofo 2016;188(8):735-745 View Article PubMed/NCBI
  28. Kang TW, Lim HK, Lee MW, Kim YS, Choi D, Rhim H. First-line radiofrequency ablation with or without artificial ascites for hepatocellular carcinomas in a subcapsular location: local control rate and risk of peritoneal seeding at long-term follow-up. Clin Radiol 2013;68(12):e641-e651 View Article PubMed/NCBI
  29. Makovich Z, Logemann J, Chen L, Mhaskar R, Choi J, Parikh N, et al. Liver tumor ablation in difficult locations: Microwave ablation of perivascular and subdiaphragmatic hepatocellular carcinoma. Clin Imaging 2021;71:170-177 View Article PubMed/NCBI
  30. Yang Y, Zhang Y, Wu Y, Chen J, Liang B, Chen Q, et al. Efficacy and safety of percutaneous argon-helium cryoablation for hepatocellular carcinoma abutting the diaphragm. J Vasc Interv Radiol 2020;31(3):393-400.e1 View Article PubMed/NCBI
  31. Sutter O, Calvo J, N’Kontchou G, Nault JC, Ourabia R, Nahon P, et al. Safety and efficacy of irreversible electroporation for the treatment of hepatocellular carcinoma not amenable to thermal ablation techniques: A retrospective single-center case series. Radiology 2017;284(3):877-886 View Article PubMed/NCBI
  32. Frühling P, Nilsson A, Duraj F, Haglund U, Norén A. Single-center nonrandomized clinical trial to assess the safety and efficacy of irreversible electroporation (IRE) ablation of liver tumors in humans: Short to mid-term results. Eur J Surg Oncol 2017;43(4):751-757 View Article PubMed/NCBI
  • Journal of Clinical and Translational Hepatology
  • pISSN 2225-0719
  • eISSN 2310-8819
  • Copyright © 2022 JCTH. All Rights Reserved.
  • Published by Xia & He Publishing Inc.
  • Address: 14090 Southwest Freeway, Suite 300, Sugar Land, Texas 77478, USA
  • Email: service@xiahepublishing.com